Verify Set Time, Date and Sampling Rate

During normal operation press the 

TIME

 button to display the year, 

month, day, hour, minutes and selected sampling rate.

Data Logging

Data Recording Modes

Manual Data Logging:

 Press the 

LOG

 button to manually log up to 

99 readings on a SD memory card (see 

Manual Data Logging Mod

e for 

full setup instructions).

Automatic Data Logging: 

Setup the meter parameters in order to 

automatically log data on a SD memory card. The number of data points 

is limited by the size of the memory card.

Note:

 It is recommended to use a class 4 SDHC memory card between 1Gb 

and 16Gb. Insert the SD memory card in the slot at the bottom of the meter. 

The card must be inserted with the label side facing the rear of the meter.

Manual Data Logging Mode

In manual mode, the LOG button is pressed to manually log a reading on 

the inserted SD card at any time. In order to setup the meter for manual 

data logging, follow steps 1 through 5 below.
1.  Set the data logging sampling rate to "0" seconds (see 

Setting the 

Data Logging Sampling Rate

 for details).

2.  Press and hold the LOG button for 2 seconds at which point the 

lower portion of the LCD will display P-X (X = memory position 

number between 1 and 99).

3.  Press the   and   buttons to select one of the 99 data memory 

positions in which to record.

4.  Press the LOG button again to save a reading to memory. "REC" will 

flash each time a data point is stored. 

Note:

 If a card is not inserted or the card is defective, the meter will flash 

"Sd -E-". In this case, power the meter OFF and try again with another SD 
memory card or verify that the card is correctly inserted.
5.  To exit manual data logging mode, press and hold the LOG button 2 

seconds to resume normal operation.

continued...

 

REED Instruments

1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com

Summary of Contents for R8100SD

Page 1: ...Data Logging Light Meter Instruction Manual R8100SD REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Page 2: ...ode 9 Data Hold 10 Recording Maximum and Minimum Readings 10 Backlight 10 Setup Mode 11 13 Setting the Time and Date dAtE 11 Setting the Data Logging Sampling Rate SP t 12 Enabling Disabling Auto Powe...

Page 3: ...By following the steps outlined in this manual your meter will provide years of reliable service Product Quality This product has been manufactured in an ISO9001 facility and has been calibrated duri...

Page 4: ...ripod mount for long term monitoring Low battery indicator and auto shut off Included Detachable Sensor Sensor Cover Soft Carrying Case Batteries Specifications Measuring Ranges Lux 2 000 20 000 100 0...

Page 5: ...16GB with SD card optional Auto Shut off Yes after 10 minutes off Kick Stand Yes Tripod Mountable Yes Low Battery Indicator Yes Power Supply 6 x AA batteries or AC Adapter optional Data Output Yes RS...

Page 6: ...Type K J Thermocouple Input Jack 5 LCD Display 6 HOLD Button 7 REC Button 8 Down Function Button 9 Enter Log Button 10 Light Sensor Input Socket 11 RS232 Output Jack 12 Reset Pin 13 Power Adapter Inp...

Page 7: ...ure Measurement Reading 3 Date Time Stamp 4 Temperature Unit of Measure 5 Measurement Reading Indicator 6 Maximum and Minimum Indicators 7 Record Mode Indicator 8 Data Hold Indicator 9 Low Battery Ind...

Page 8: ...n LiGHT for light meter and tP for Type K J Thermometer measurement modes of operation 2 Release the Function button to confirm selection Light Measurement 1 When the meter is off plug the probe into...

Page 9: ...nd buttons simultaneously until the LCD display shows a zero value Type K J Thermocouple Measurement Mode 1 Select the tP function see Selecting Measurement Modes for details 2 Plug the optional Type...

Page 10: ...and minimum readings 2 While in recording mode A Press the REC button once and the maximum value will appear on the display as indicated by REC MAX B Press the REC button again and the minimum value...

Page 11: ...r automatically exit out of the Setup mode if no key is pressed within 7 seconds Setting the Time and Date dAtE 1 Press the ENTER button when dAtE appears on the LCD 2 Press the and buttons to adjust...

Page 12: ...ENTER button to confirm selection and skip to the next parameter Note At any time you can press the POWER button to exit the Setup mode and resume normal operation Enabling Disabling the Beeper bEEP F...

Page 13: ...nd resume normal operation It is recommended that new SD cards should be formatted prior to first use If the formatting process fails or if no card is inserted the meter will display Sd E Selecting th...

Page 14: ...essed to manually log a reading on the inserted SD card at any time In order to setup the meter for manual data logging follow steps 1 through 5 below 1 Set the data logging sampling rate to 0 seconds...

Page 15: ...e the data logging session press the LOG button and REC will stop flashing To resume press the LOG button again 4 To end the current data logging session press and hold the LOG button for 2 seconds Tr...

Page 16: ...om the RS 232 output connect RS 232 USB cable between the product and terminal PC and use the following setting to view the data stream Terminal Settings Bits per second 9600 Data bits 8 Parity None S...

Page 17: ...vice Center for repair Battery Replacement When the low battery icon appears on the LCD the batteries must be replaced 1 Remove the two 2 Phillips screws on the back of the meter directly located abov...

Page 18: ...all accessories and replacement parts visit your product page on www reedinstruments com Frequently Asked Questions FAQ s I cannot turn off my meter do you know why Often times the meter cannot be tu...

Page 19: ...cient LED white daylight 0 99 LED RED light 0 516 LED AMBER YELLOW light 0 815 LED GREEN light 1 216 LED BLUE light 1 475 LED PURPLE light 1 148 Product Care To keep your instrument in good working or...

Page 20: ...2127 or info reedinstruments com to discuss the claim and determine the appropriate steps to process the warranty Product Disposal and Recycling Please follow local laws and regulations when disposin...

Page 21: ...Test Measure with Confidence Check out our latest Products REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Page 22: ...REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Reviews: