5.  Take care when making measurements if the voltages are greater 

than 25VAC rms or 35VDC. These voltages are considered a shock 
hazard.

6.  Always discharge capacitors and remove power from the device 

under test before performing Diode, Resistance or Continuity tests.

7.  Remove the battery from the meter if the meter is to be stored for 

long periods.

Features

•  Autoranging multimeter and non-contact voltage detector
•  Built-in flashlight
•  Diode check and continuity functions
•  Auto power off and data hold
•  Double molded housing and test leads
•  CAT III 1000V, CAT IV 600V safety rating
•  Includes test leads and batteries

Instrument Description 

1.  Non-contact AC voltage 

detector probe tip

2.  Non-contact AC voltage 

indicator light

3.  3 1/2 Digit (2000 count) 
4.   MODE button
5.   Function switch
6.   Flashlight
7.   Flashlight button
8.   Data Hold button
9.   Battery Cover
10.  Test leads

 

REED Instruments

1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com

Summary of Contents for R5009

Page 1: ...R5009 3 in 1 Pocket Autoranging Digital Multimeter INSTR INSTR Model Instruction Manual REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Page 2: ...fety Precautions 1 Improper use of this meter can cause damage shock injury or death Read and understand this users manual before operating the meter 2 Make sure any covers or battery doors are proper...

Page 3: ...nging multimeter and non contact voltage detector Built in flashlight Diode check and continuity functions Auto power off and data hold Double molded housing and test leads CAT III 1000V CAT IV 600V s...

Page 4: ...0 rdg 5d Resolution 0 1 1 10 100 1 10k Display 2 000 count LCD display Display Hold Yes Relative Mode Yes Diode Test Yes Continuity Check Audible signal if resistance 150 Voltage Detector Yes Built i...

Page 5: ...1 Set the function switch to the A mA position 2 For current measurements up to 2000 A DC AC set the function switch to the mA position 3 Press the MODE button to indicate DC AC on the display 4 Remo...

Page 6: ...shock never measure continuity on circuits or wires that have voltage on them 1 Set the function switch to the position 2 Press the MODE button to indicate on the display 3 Touch the test probe tips t...

Page 7: ...tatic electricity or other sources of energy may randomly trip the sensor This is normal operation Hold Button The data hold function allows the meter to freeze a measurement for later reference 1 Pre...

Page 8: ...the old fuse and install the new fuse into the holder 6 Always use a fuse of the proper size and value 0 2A 250V fast blow for the 200mA range 7 Align the center board with the connectors and gently...