57
e) Connection to the Receiver
Connect the connection cable for the receiver connection to the socket „ST3“ of the composite signal converter. The
connection sockets 1 - 10 of the cable are intended for the receiver connection.
The contacts of the connection cable are assigned as follows:
Contact 10 = Channel 1
Contact 9 = Channel 2
Contact 8 = Channel 3
Contact 7 = Channel 4
Contact 6 = Channel 5
Contact 5 = Channel 6
Contact 4 = Channel 7
Contact 3 = Channel 8
Contact 2 = GND/Minus (-)
Contact 1 = 5 V/Plus (+)
The signals of the 8 inputs (channels 1 - 8) are measured and processed by the composite signal converter. All
available signals are combined into a composite signal pursuant to the specifications for RC remote control systems
(pulse width between 1 ms and 2 ms). Due to measuring of the signals and signal processing, there will be a delay of
one frame length. However, this has no effect during operation and is therefore only mentioned for the same of
completeness.
The measured servo signals may appear in any order, parallel, in sequence or overlapping. There is no limitation, so
that the composite signal converter can be used for all common systems. A synch break between the different signals
is also not required.
Important!
Observe that the composite signal converter inputs are assigned without gaps!
In a 6-channel system, this means inputs 1 - 6 must be used rather than, e.g., 1 - 4 and then 6 - 7. With this
assignment, the electronics would not recognise channels 6 and 7!
C1
R9 R13
R10 R14
R3 R7 R11 R15
R4
R8
R12
R16
C6
ST3
ST1
1
2
5
6
ST2
1
10
Figure 7
Summary of Contents for 450 ARF QC09
Page 166: ...166 ...
Page 167: ...167 ...