18
8540581 - 29/09/2010 - Rev.10
Curtain
free
Curtain
occupied
CONFIGURATION OF THE TYPE OF BLANKING
The Type of Blanking of the ADMIRAL AX BK light curtain is set with suitable connections on
the M12 8-pin connector of the Receiver (Table 9).
CONNECTIONS
FUNCTIONING MODE
SEL_A (pin 5)
connected to:
0VDC
SEL_B (pin 6)
connected to:
0VDC
SEL_C (pin 4)
connected to:
0VDC
No blanking
SEL_A (pin 5)
connected to:
0VDC
SEL_B (pin 6)
connected to:
24VDC
SEL_C (pin 4)
connected to:
24VDC
Blanking Without Object
Presence Obligation – Mode
A1
SEL_A (pin 5)
connected to:
24VDC
SEL_B (pin 6)
connected to:
0VDC
SEL_C (pin 4)
connected to:
24VDC
Blanking Without Object
Presence Obligation - Mode
A2
SEL_A (pin 5)
connected to:
24VDC
SEL_B (pin 6)
connected to:
24VDC
SEL_C (pin 4)
connected to:
0VDC
Blanking Without Object
Presence Obligation - Mode
A3
SEL_A (pin 5)
connected to:
OSSD1 (pin 1)
SEL_B (pin 6)
connected to:
OSSD2 (pin 3)
SEL_C (pin 4)
connected to:
24VDC
Blanking With Object
Presence Obligation - Mode
B1
SEL_A (pin 5)
connected to:
OSSD2 (pin 3)
SEL_B (pin 6)
connected to:
OSSD1 (pin 1)
SEL_C (pin 4)
connected to:
0VDC
Blanking With Object
Presence Obligation - Mode
B2
Table 9
It is not possible to modify the configuration of the type of Blanking with the light
curtain operating. The system must first of all be switched off and then on again.
MOBILE
OBJECT