TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS OF VISION BARRIERS VXL
Protected height
mm
160
–
1810
Resolutions
mm
30
–
40
Working range
m
0,3
8
Safety outputs
2 PNP
–
500mA @ 24VDC
Response time
ms
4
37 (see tables for specific models)
Internal test frequency
every 500ms (2Hz)
Power supply
VDC
24
20%
Connections
Connectors M12 5/8-poles
Max. conn. length
m
100
Operating temperature
°C
0
+55°C
Storage temperature
°C
-20
+70°C
Protection rating
IP 65
Dimensions of section
mm
35 x 45
Max. consumption
W
2 (Emitter)
2 (Receiver)
Light curtain lifetime
20 years
Safety level
Type 2
IEC 61496-1:2004
IEC 61496-2:2006
SILCL 2
IEC 62061:2005
PL d - Category 2
ISO 13849-1:2006
30 mm Resolution Models
153
303
453
603
753
903
1053
1203
Number of beams
8
16
24
32
40
48
56
64
Response time
ms
7
11,5
16
20
24
28,5
33
37
Overall barrier ht.
mm
261
411
561
711
861
1011
1161
1311
PFHd *
2,44E-08 3,56E-08
4,68E-08
5,8E-08
6,92E-08
8,05E-08
9,17E-08
1,03E-07
DCavg
#
94,0%
93,7%
93,6%
93,5%
93,5%
93,4%
93,4%
93,4%
MTTFd
#
years
100
93,24
82,22
73,53
CCF
#
80%
40 mm
Resolution Models
304
454
604
754
904 1054 1204 1354 1504 1654 1804
Number of beams
10
15
20
25
30
35
40
45
50
55
60
Response time
ms
8
11
13,5
16
19
22
24
27
30
32
35
Overall barrier ht.
mm
411
561
711
861
1011
1161
1311
1461
1611
1761
1911
PFHd *
2,97E-08
3,79E-08
4,61E-08
5,44E-08
6,26E-08
7,08E-08
7,9E-08
8,73E-08
9,55E-08
1,04E-07
1,12E-07
DCavg
#
94,0%
93,9%
93,8%
93,7%
93,7%
93,7%
93,7%
93,6%
93,6%
93,6%
93,6%
MTTFd
#
years
100
91,58
83,18
76,19
70,29
65,24
CCF
#
80%
Multibeam Models
VXL2B
VXL3B
VXL4B
Number of beams
2
3
4
Distance between beams
mm
500
400
300
Response time
ms
4
4,5
5,5
Overall barrier ht.
mm
711
1011
1111
PFHd *
1,45E-08
1,52E-08
1,59E-08
DCavg
#
94,7%
94,8%
94,8%
MTTFd
#
years
100
CCF
#
80%
* IEC 62061
#