VISION VXL
10
8540615 • 19/12/2014 • Rev.8
RECEIVER CONNECTIONS
8 poles M12 connector
PIN
COLOR
NAME
TYPE
DESCRIPTION
FUNCTIONING
2
Brown
24VDC
-
+24VDC power supply
-
7
Blue
0VDC
-
0VDC power supply
-
8
Red
FE
-
Ground connection
-
1
White
OSSD1
OUTPUT
Safety
static outputs
PNP active high
3
Green
OSSD2
OUTPUT
5
Grey
SEL_A
INPUT
Barrier configuration
According the normative EN61131-2
(ref. Par.
"Configuration
and operation modes"
)
6
Pink
SEL_B
INPUT
4
Yellow
K1_K2
INPUT
External contactors
Feedback
Table 2
WARNINGS REGARDING THE CONNECTION CABLES
For connections over 50m long, use cables with a cross-section area
of 1 mm
2
.
The power supply to the barrier should be kept separate from that to other
electric power equipment (electric motors, inverters, frequency converters) or
other sources of disturbance.
Connect the Emitter and the Receiver to the ground outlet.
The connection cables must follow a different route to that of the other power
cables.