Technical data
14 — English
Vacuum spray degassing — 06.07.2016 - Rev. B
5
Technical data
Note!
The following values apply for all systems:
– Permissible flow temperature:
– Permissible operating temperature makeup
degassing:
– Permissible ambient temperature:
– Permissible operating gauge pressure:
– Maximum inlet pressure for makeup:
– Makeup capacity:
– Separation level, dissolved gases:
– Separation level, free gases:
– Degree of protection:
120 °C
0 °C – 30 °C
0 °C – 45 °C
8 bar
6 bar
0.05 m³/h
≤ 90 %
100 %
IP 54
5.1
Electrical system
Type
Power output
(kW)
Power supply
(V / Hz)
Fusing
(A)
Number of RS-
485 interfaces
I/O module Electrical voltage
control unit
(V, A)
Noise level
(dB)
30
0.47
230 / 50
10
1
No
230, 4
55
30 GL
0.47
230 / 50
10
1
No
230, 4
55
5.2
Dimensions and connections
Type
Weight
(kg)
Height
(mm)
Width
(mm)
Depth
(mm)
Degassing
device
connection
Degassing
system
connection
Make-up
connection
30
13.5
660
545
290
IG ½ "
IG ½ "
IG ½ "
30 GL
13.5
660
545
290
IG ½ "
IG ½ "
IG ½ "
5.3
Operation
Type
System volume
(100% water)
(m³)
System volume
(50% water)
(m³)
Working
pressure
(bar)
Permissible operating
gauge pressure
(bar)
Setpoint overflow
valve
(bar)
Operating
temperature
(°C)
30
1
–
0.5 – 3
8
–
>0 – 70
30 GL
–
2.5
0.5 – 3
8
–
>0 – 70