16
4. This sequence will then repeat for STEP 2 and then STEP 3 with-
out the VGreen 085 stopping.
5. At the end of STEP 3, the VGreen 085 will wait if necessary for the
completion of the 24-hour schedule. During this waiting period (if
applicable), all of the “active step LEDs” will remain OFF. However,
the START LED will still be illuminated. After completion of the 24
hour schedule, the system restarts at STEP 1 and this cycle will
repeat indefinitely until the user presses the STOP key.
NOTE:
Pressing a STEP key other than for the STEP currently running
will cause an immediate transition to the newly selected STEP. The
VGreen 085 will continue with the programmed schedule from that point
forward.
NOTE:
If STOP is pressed during normal schedule operation, the 24
hour schedule will stop. When START is pressed again, the 24 hour
schedule will start from STEP 1.
NOTE:
If power is lost while the VGreen 085 is running a 24 hour sched-
ule, upon restoration of power the VGreen 085 will start the 24 hour
schedule from STEP 1.
NOTE:
If a digital input (provided from an external source) is detected,
the VGreen 085 will start running on the STEP 1, STEP 2, STEP 3, or
OVERRIDE speed corresponding to the digital input. Upon removing
the digital input (provided from an external source), the VGreen 085 will
stop and the user will need to press START to begin the 24 hour sched-
ule operation. However, if START was already pressed prior to receiv-
ing a digital input, then the VGreen 085 will resume running the 24 hour
schedule once the digital input is removed.
NOTE:
Pressing STOP at any time turns the VGreen 085 OFF and
clears the start time for the 24 hour schedule.