5
• Ability to configure
freeze protection
temperature.
• Ability to view actual speed and power of the VGreen 085 in real time.
• Ability to adjust the VGreen 085 motor speed in 25 RPM
increments (to fine tune flow for certain pool installations).
• Battery backup to store time setting.
3
Quick Start Instruction
3.1 Quick Start Guide
(Using the factory default schedule)
The following table describes the factory default settings for DURATION
and SPEED order:
Pressing the START key will start the VGreen 085 based on the factory
default schedule.
NOTE:
If power is cycled to the VGreen 085 and the user does not
press the STOP key, the VGreen 085 will
automatically
start and run
the programmed default schedule shown in the chart above. This
feature ensures that the VGreen 085 will re-start in the event of a power
outage.
Button
Duration
(In Hours)
Speed
(In RPM)
STEP 1
4
3100
STEP 2
4
2600
STEP 3
8
1600
OVERRIDE
2
3450
If power is connected to the VGreen 085 motor, pressing any of the following buttons
referred to in section 3 could result in the motor starting. Failure to recognize this could
result in personal injury or damage to equipment.