Manual - TC.P Quadro
Software options
2016-08-05
116/330
V04.52
4
In the case of several reference values within a function se-
quence, several function blocks can be active at the same time.
The shortest function block defines the duration of the function
sequence.
The pause time and the number of repetitions apply equally to
all function blocks within a function sequence.
1
2
Fig. 60
Example of the capabilities of the function generator.
-1- Exponential envelope, specified in the TFE
-2- Result: a sine wave function that decays correspondingly -1-.
In the example 2 repetitions have been defined.
The following events (“Trigger mode”)
can trigger a function sequence
:
VOLTAGE ON (“Voltage on”)
As soon as the output power is activated at the output of the
power supply.
Manual triggering (“Manual”)
Manual triggering is possible ¡n the TopControl application or
with the aid of the HMI/RCU.
A
nalogue interface X105 (“High level on X105/19”)
If there is a high level on pin 19 of the interface.
Definition of reference values prior to a trigger event
The nature of the trigger can be specified in the TopControl application
and HMI/RCU. Up until the trigger event, the set values specified by the
active interface apply, e.g.:
RS-232 interface
Set values defined via the TopControl application.
HMI/RCU
Set values defined via HMI/RCU.
Analogue interface X105
Set values defined via the analogue interface.