Manual - TC.P Quadro
Introduction and overview
2016-08-05
144/330
V04.52
6
TopCon as single device or master device
The following interfaces can operate the single device/master device
with the following tasks:
Analogue interface,
Set value specification for U, I, P and R
Internal
Actual value output for U, I
HMI/RCU (option),
Set value specification, actual value output,
start/stop function sequence,
display errors/warnings, system information
TopControl application,
(via DLL function library)
Set value specification, actual value output,
complete function generator (option),
scope/int. data acquisition,
display errors/warnings, system information,
parameterisation/adjustment
LabView,
Virtual remote control for base functions available
Access in principle to all functions in the DLL
Proprietary software,
Access in principle to all functions in the DLL,
using custom software (C/C++, C#, Visual Basic).
Possibly also access via LabView
Slave device
in the multi-unit system,
Passive receiver (reference values),
passing on and reception of the error status