Manual - TC.P Quadro
TopControl application
2016-08-05
188/330
V04.52
6
STATUS tab
– parameter description (continued)
6
Internal device supply,
read-only indication
Indication of the device-internal supply voltages. Comparison of set value and
actual value. The indication is dependent on the selection in Source selector
-
8-
.
7
Auto refresh,
check box
ON
If selected the refresh is activated (default)
If cleared the window must be refreshed manually using
<Refresh Display>.
Times
Selection of the refresh time: 1 s (default), 2 s, 5 s
<Refresh Display> Manual refresh of the window.
Can be selected if “ON” is cleared.
8
Source selector,
list box
Selection active
On the master device in the multi-unit system.
Selection inactive
On
single device, or slave device in a multi-unit system.
Possible selections with Source selector active
“Master”
All parameters are displayed.
“Slave 0xXX”
The following
parameters are displayed
-1-, -2-, -3-, -4-, -9-.
“System”
The following
parameters are displayed
-1-, -2-, -3-, -4-, -9-.
9
Warning and error messages,
read-only indications
The indication of the warnings and error messages is dependent on the selec-
tion in Source selector
-8-.
Red:
There is an error. More information in
-10-
Output is electrically isolated. ERROR status
Orange:
There is a warning. More information in
-10-
Output provides power. WARNING status
Grey:
There is no error and no warning.
10
Buttons
for warning and error details
<Show Errordetail>
In case of an error
Button is activated (black font).
Makes it possible to open error details.
See Table 107, page 186.
No error
Button is deactivated (grey font).
Not
possible to open details.
<Show Warndetail>
Similar to <Show Errordetail>.
Table 108 Parameters on the <STATUS> tab.