Manual - TC.P Quadro
TopControl application
2016-08-05
195/330
V04.52
6
Manual triggering
Conditions for manual triggering are:
(i.e. the <Start> button can be clicked)
In the “Trigger mode” list box the entry “Manual” has been se-
lected.
The TopCon power supply is in the “VOLTAGE_ON” state, see
<CONTROL> tab.
1
2
3
4
Fig. 115
Options during manual triggering.
<FUNCGEN> tab
– “Trigger mode” group
1
<Start>, button
is clicked
Trigger event triggers the function sequence.
Button changes the function to <Stop>
-2-
<Pause>
-3-
button is activated.
If in Table 112, page 194 a specific number of runs for the base functions
has been defined, the button changes automatically to <Stop>
-2-
as soon
as this number has been run
.
2
<Stop>, button
is clicked
Function sequence is ended and the TopCon power supply adopts the
output value set in
Table 112, page 194.
Function sequence can be started again via <Start>
-1-
.
3
<Pause> button
is clicked
The function sequence is paused
The actual output value is retained.
Button changes the function to <Continue>
-4-.
4
<Continue>
button
is clicked
The function sequence is continued.
Button changes the function to <Pause>
-3-
.
Table 113 Options on manual triggering.