Manual - TC.P Quadro
TopControl application
2016-08-05
197/330
V04.52
6
1
3
2
4 5
10
6
8 9
12
11
7
<FUNCGEN> tab
– “Function Block” group (continued)
3
Base Function,
group
Entries in the list box for the base functions:
“Sine”
For sine function
hidden:
-7-
,
-11-
“Square”
For square function
hidden:
-11-
“Triangle”
For triangle function
hidden:
-11-
“User defined” For user-defined function
hidden:
-6-
,
-7-
,
-11-
selected: “Edit user defined...”, button
selected: “allow manual scaling”, check box
For further information on the creation of user-defined
curves see Fig. 118, page 200.
“AAP”
For Application Area Programming function
hidden:
-6-
,
-7-
,
-11-
selected: “Edit AAP”, button
selected: “allow manual scaling”, check box
For further information on the creation of an
AAP function see Fig. 120, page 203.
allow manual scaling,
check box
Selected:
Activated for entry:
-4-
,
-5-
User-defined function or AAP curves is scaled to
the amplitude
-4-
and offset
-5-
to be entered.
Cleared
Deactivated for entry:
-4-
,
-5-
The amplitude and offset values are defined by the
function definition for the user-defined functions or AAP
curve.
4
Amplitude,
text box, the unit depends on the reference value in
-1-
Entry of the amplitude value for the base function.
Depending on the selection in
-3-
the text box is activated or not available.
Value range:
Negative nominal value
– positive nominal value
5
Offset,
text box,
the unit depends on the reference value in
-1-
Offset value for the base function
Depending on the selection in
-3-
the text box is activated or not available.
Value range:
Negative nominal value
– positive nominal value
6
Frequency
, text box
Frequency for the base function.
Cannot be applied to user-defined function and with AAP. There the time is
defined individually for each separate point or there is no time dependency.
Value range:
0.001Hz
– 500 Hz
The table is continued overleaf.