Setting up the hardware/connecting a TopCon power supply
Checking device and accessories
1 TopCon power supply (single device).
1 dummy plug Sub-D 25-pin,
“Interlock” for X105 interface.
1 dummy plug Sub-D 9-pin,
“Interlock and CAN-Term”.
If RCU is available,
RCU (bench unit) and connection cable.
Preparing interlock and communication bus correctly
For an illustration see Fig. 27 and Fig. 28, from page 62.
Connect the control interface (X105) to the 25-pin dummy plug
(device rear side)
The CAN bus for the device communication is connected.
Situation: no RCU (Remote Control Unit) available.
The communication and interlock interface (X101) on the rear
side of the TopCon power supply is terminated using the “Inter-
lock and CAN-
Term” dummy plug (9-pin) (device rear side).
Situation: RCU (Remote Control Unit) available.
Connect the connection cable to the communication and inter-
lock interface (X101) on the rear side of the TopCon power sup-
ply. The other end is connected to the RCU interface
(X101).
The “Interlock and CAN-Term” dummy plug is connected to con-
nector X102 on the RCU. (Device rear side)