Manual - TC.P Quadro
TopControl application
2016-08-05
214/330
V04.52
6
“Select signal” window – parameters (continued)
3
<OK>/<Cancel>,
buttons
<OK>
Accept a selected signal variable (blue background) and
return to the <SCOPE> tab view
The signal variable is selected for the channel.
<Cancel>
Return to the <SCOPE> tab view without applying a signal
variable to the channel.
4
Select group,
list box
Only the variables that are part of the selected signal group are indicated in
the signal list
-2-
.
Mostly a group is divided into the variables for a single device (“..module”) or
for a multi-
unit system (“...system”).
The following signal groups are available from the standard gridfile:
Act. values
Group of actual values (output values).
Controller
Indication of the active controller and its operation.
Ref. values
Reference values, are defined internally in the device or via
an interface.
State
Signal variables for the device status or system status, such
as READY, RUN, WARN, ERROR etc. A corresponding
output value is assigned to each status, see the description
in the “note” column in the signal list
-2-
.
Temperature
Signal variables for the device-internal temperature at the
heat sinks for the IGBT and the rectifier.
5
Filter,
text box
It is possible to enter individual letters. A search is made for the string entered
and the list updated immediately, independent of the position of the letters in
the variable name.
Two colour states for the text box indicate the match status
Green
String exists.
Red
String does not exist.
White
Filter is inactive, text box blank
Table 124
Parameters in the “Select signal” window.
Description of the standard scope gridfile
The following signals are arranged as per their group membership
(“group” or “select group”) in the standard gridfile. See Table 124, 214.