Manual - TC.P Quadro
TopControl application
2016-08-05
222/330
V04.52
6
“Time resolution” and “#sampl. points” groups
3
2
3
1
2
4
Fig. 131
“Time resolution” and “#sampl. points” groups.
“Time resolution”/“#sample points” groups – parameters
1
#sampl.points,
text box
Number of measurement points (MP) on a signal curve that are saved.
The more measurement points are saved, the longer the transfer from the
memory from the memory in the TopCon to TopControl will take.
Value range:
1
– 1024 MP; default: 1024 MP; step width: 1 MP
2
Time resolution,
text box
Period between two measurement points
-1-
The value range is dependent on the unit selected
-3-
Value range:
50 µs
– 3276.75 min.
3
Time resolution,
list box
Selection between ms, s, min.
4
Record time,
read-only indication
The maximum recording time is the product of “Time resolution”
-2-
and
“#sample. points”
-1-
Table 132 Parameters for
the “Time resolution” and “#sample.points” groups.