Manual - TC.P Quadro
TopControl application
2016-08-05
234/330
V04.52
6
3
4
1
2
5
Fig. 139
Overview of <ADJUST 2> tab.
<ADJUST 2> tab
– parameter overview
1
Sense voltage measurement,
group
Calibration of the sense.
The maximum and minimum sense voltage is calibrated using the gain and
the offset.
The indication on the right shows the allocation between the actual measured
value and the sense voltage.
2
DC link voltage measurement,
group
Calibration of the intermediate circuit voltage measured value.
The maximum and minimum intermediate circuit voltage is calibrated using
the gain and the offset.
The indication on the right shows the allocation between the actual measured
value and the voltage.
3
RMB measurements,
group
Calibration of voltage and current measurements on the remote measurement
box (RMB).
The maximum and minimum RMB voltage and current is calibrated using the
gain and the offset.
The indication on the right shows the allocation between the actual measured
value and the voltage or current.
4
Rectifier temperature measurement, group
Calibration of the measured temperature value at the rectifiers.
The offset is used to calibrate to the actual temperature present.
In the lower temperature range accuracies up to ± 2 °C are possible.
The indication on the right shows the allocation between the actual measured
value and the temperature indicated.
5
Store settings,
button
Settings made on the <ADJUST 2> tab are permanently saved. The actual
parameter set is saved from the RAM to the flash PROM in the TopCon power
supply.
Table 140 Overview of the <ADJUST 2> tab.