6.4.7.9. Tab
– <PARAMETERS>
User level: from Power User
The <PARAMETERS> tab is used to modify internal control parame-
ters. TopCon is a reactive system that communicates with other sys-
tems (e.g. user interface) via these control parameters. These control
parameters are saved in so-called gridfiles.
Gridfiles contain the allocation of variable names to the actual hardware
addresses used in the controller. This allocation may change on version
changes. Variable/address allocations can be edited via the
<PARAMETERS> tab.
Appropriate gridfiles are provided by Regatron support.
Damage to the TopCon power supply possible!
Modified hardware addresses can cause the system in the
TopCon power supply to crash continuously.
Modified parameters and variables can change the safety lim-
its in the TopCon power supply, which can cause damage to
the device.
Avoidance:
Please contact Regatron support first.
Only make changes that are absolutely necessary.
Make changes carefully,
take your time with the changes.
If the firmware and gridfile version do not match, a warning
appears. Contact support immediately.
3
7
1
2
5
6
4
Fig. 140
Overview of the <PARAMETERS> tab.
CAUTION