Manual - TC.P Quadro
0) Internal
2016-08-05
268/330
V04.52
9
9.1. Error groups
9.1.1.
0) Internal
Flash
Code
Error
Error
message
TopCon (Long)
Description
Possible Cause
Counteraction
1-1
00
Invalid system state
An invalid internal state was detect-
ed.
(Used for debugging pur-pose).
In the case of repeated occur-
rence refer to customer support .
no
1-2
01
Invalid module
state
An invalid internal state was detect-
ed.
(Used for debugging pur-pose).
In the case of repeated occur-
rence refer to customer support .
no
1-3
02
Calculation Over-
flow
The internal calculation overflow is
prevented.
Wrong parameters are set. Possily
after a firmware update
Make sure that the correct Update-Gridfile has
been used when applying the firmware update
1-4
03
Flash full
Internal non-volatile memory is full
Tried to e.g. store more function
sequneces than possible.
Delete some unused function sequences an try
again
1-5
04
EEPROM table
write
Write error in the non-volatile
memory when storing device param-
eters.
You have made an update from
Version V4.11.33 or older to
V4.11.34 or new-er.
After power up activate button "Store settings" and
restart device.
1-6
05
Flash timeout
Timeout while writing or deleting a
flash page.
In the case of repeated occur-
rence refer to customer support
no
1-7
06
ADC sequence
AD converter sequence is incorrect.
A strong EMI pulse affects the AD
data stream or hardware defect.
Extensive measures to thoroughly earth the device
is needed.
Find the EMI sources e.g. contactors without free
wheeling diodes
1-8
07
Invalid EEPROM
table
Empty or invalid table of device pa-
rameters.
In the case of repeated occur-
rence refer to customer support.
no
1-9
08
Requested state
not available
An unexpected change of state was
detected. (Used for debugging pur-
pose).
In the case of repeated occur-
rence refer to customer support.
no
1-10
09
Thyristor not swit-
ched on
The Thyristor switch for DC link load
resistor isn’t switched on.
Tried to switch on output (voltage-
on) when DCLink voltage and/or
mains voltage error limit is
reached but that error was not yet
reported because of a pro-
grammed delay.
Make sure mains voltage of each phase is within
valid range.