Manual - TC.P Quadro
1) Internal (PDSP)
2016-08-05
271/330
V04.52
9
Flash
Code
Error
Error message
TopCon (Long)
Description
Possible Cause
Counteraction
2-9
18
SCI framing
Various errors on interface RS232.
On host side, a wrong level for an
inactive state exists, while the
RS232-
interface hasn’t been
opened
Update the peripherals DSP to at least version
0.11.
Start TopControl: when running, the interface is
opened.
Acknowledge the error (“Clear error”).
2-10
19
SCI break
Various errors on interface RS232.
2-11
1A
Unknown SCI sta-
tus bit
Undefined internal communication.
(Used for debugging purpose).
In the case of repeated occur-
rence refer to customer support .
no
2-12
1B
Unknown CAN
status bit
Undefined internal communication.
(Used for debugging purpose).
In the case of repeated occur-
rence refer to customer support .
no
2-13
1C
Unknown PDSP
package
Undefined internal communication.
(Used for debugging purpose).
In the case of repeated occur-
rence refer to customer support .
no
2-14
1D
Package from not
initialised mailbox
Received a CAN pack-age from a
not initialized CAN mailbox.(Used for
debugging purpose).
Occurs at start with firm-ware
v4.11.30 while con-trolling at least
4 inter-connected devices. Is to be
ignored in this case.
In other constellations, refer to the
customer support
no
2-15
1E
PDSP communica-
tion stopped
Communication to the peripheral
DSP
failed.
In the case of repeated occur-
rence refer to customer support.
no
2-16
1F
SCI timeout within
a talk frame.
Timeout while receiving a TALK
frame by RS232
RS232 communication was dis-
connected or interrupted.
See above errors 15-19
2-16
1F
SCI timeout within
a talk frame.
Timeout while receiving a TALK
frame by RS232
Consequence of error 18.
See above errors 15-19
2-16
1F
SCI timeout within
a talk frame.
Timeout while receiving a TALK
frame by RS232
On host side (PC) the implemen-
tation of the TALK-protocol is too
slow.
All bytes of a TALK Frame have to be sent be-
tween 5 ms (peripherals DSP version V0.09 /
V0.10) and 200ms (from PDSP version v0.11 up-
wards and devices with CTR4.20).