Manual - TC.P Quadro
2) Output current
2016-08-05
273/330
V04.52
9
Flash
Code
Error
Error message
TopCon (Long)
Description
Possible Cause
Counteraction
3-7
26
TC.LIN Overcurrent
The TC.LIN output current exceeded
the upper current level for a specific
time.
Cf. „21) Overcurrent Isek“
no
3-8
27
TC.LIN Overload
Safe Operating Area (SOA) exceed-
ed
Cf. „21) Overcurrent Isek“
Reduce the output current and/or drop voltage
over TC.LIN.
3-9
28
Arc detection
threshold reached
3-10
29
Overcurrent Isek
Q4
Output current in sink operation (Q4)
exceeds the set level during a pa-
ricular time. Cf. 21)
Cf. „21) Overcurrent Isek“
3-11
2A
Overcurrent Isek
Q4 (level derated
by temperature)
Cf. 25)
Cf. „21) Overcurrent Isek“
3-12
2B
Overcurrent output
inductor
Inductor current on DC output ex-
ceeds specified limit
Cf. „21) Overcurrent Isek“
3-13
2C
Overrcurrent DC
Discharge Unit
Current on DC Discharge Unit ex-
ceeds specified limit
A battery is connected to the out-
put.
The connected load violate the
specified limits.
Check if no battery is connected to the ouput.
Check if the connected load does not violate the
specified limits.
3-16
2F
Plasma arc not
detected on all
modules
Not present in standard firmware
Not present in standard firmware
Not present in standard firmware