Manual - TC.P Quadro
C) Login
2016-08-05
298/330
V04.52
9
Flash
Code
Error
Error message
TopCon (Long)
Description
Possible Cause
Counteraction
13-7
C6
TC.LIN missing
The use of TC.LIN devices was ena-
bled in TopCon master device, but at
start-up no TC.LIN device was
found.
TC.LIN is not switched on at all or
is switched on too early or too
late.
Switch on TC.LIN within a 20s duration prior to
switching on the TopCon master.
13-7
C6
TC.LIN missing
The use of TC.LIN devices was ena-
bled in TopCon master device, but at
start-up no TC.LIN device was
found.
TC.LIN communication cable is
not plugged in or defective.
Check if cable is safely mounted and if necessary
replace it with another one.
13-7
C6
TC.LIN missing
The use of TC.LIN devices was ena-
bled in TopCon master device, but at
start-up no TC.LIN device was
found.
CAN terminating resistors (CAN-
Term DSub jack) not plugged in.
Connect appropriate termination resistors (provid-
ed).
13-7
C6
TC.LIN missing
The use of TC.LIN devices was ena-
bled in TopCon master device, but at
start-up no TC.LIN device was
found.
Internal supply of TC.LIN defective Contact the customer support.
13-8
C7
Master did not re-
ceive all RFL sub-
frames from
HMI/RCU
Missing CAN init data detected
Communication interruptions dur-
ing the initialising phase.
Cf. 60) and 61)
13-9
C8
CAN protocol ver-
sion is not identical
CAN protocol or software is not iden-
tical on all devices.
The software version of all devices
involved have to be compatible
with that one of the master device.
The software version of all devices involved have
to be compatible with that one of the master de-
vice.
13-10 C9
Software version is
not identical
CAN protocol or software is not iden-
tical on all devices.
The software version of all devices
involved have to be compatible
with that one of the master device.
The software version of all devices involved have
to be compatible with that one of the master de-
vice.
13-11 CA
Slave CAN protocol
version is not iden-
tical
CAN protocol or software is not iden-
tical on all devices.
The software version of all devices
involved have to be compatible
with that one of the master device.
The software version of all devices involved have
to be compatible with that one of the master de-
vice.
13-12 CB
HMI/RCU CAN
protocol version is
not identical
The HMI/RCU version doesn’t match
to the current firmware.
Contact the customer support to
receive a compatible version.
Contact the customer support to receive a compat-
ible version.