Manual - TC.P Quadro
C) Login
2016-08-05
299/330
V04.52
9
Flash
Code
Error
Error message
TopCon (Long)
Description
Possible Cause
Counteraction
Only
HMI
CC
HMI/RCU did not
receive CFL
A HMI/RCU has not received a re-
quest to log on to the system.
No master device has been de-
fined.
You have to assure that a master (Module ID=0)
is available.
Only
HMI
CC
HMI/RCU did not
receive CFL
A HMI/RCU has not received a re-
quest to log on to the system.
The controller board has no sup-
ply voltage (LED's remain dark
when switching on).
In case of repeated occurrence refer to customer
support.
Only
HMI
CC
HMI/RCU did not
receive CFL
A HMI/RCU has not received a re-
quest to log on to the system.
Master device has been switched
on before the HMI/RCU is
switched on.
Switch on the master always after all slaves, but
within a 10 seconds period.
Only
HMI
CC
HMI/RCU did not
receive CFL
A HMI/RCU has not received a re-
quest to log on to the system.
Master device is not switched on
until to the end of 10s HMI/RCU
timeout.
Switch on the master always after all HMI/RCU
devices, but within a 10 seconds period.
Only
HMI
CC
HMI/RCU did not
receive CFL
A HMI/RCU has not received a re-
quest to log on to the system.
Master device is not switched on
until to the end of 10s HMI/RCU
timeout.
Switch on the TC.MAC device earlier or update the
firmware to V5.20.00 (Up to this version the
timeout time is 20 seconds)
Only
HMI
CC
HMI/RCU did not
receive CFL
A HMI/RCU has not received a re-
quest to log on to the system.
Master slave cable or RCU cable
not connected.
Check cabling for correct mounting.
Only
HMI
CC
HMI/RCU did not
receive CFL
A HMI/RCU has not received a re-
quest to log on to the system.
TopCon devices of the generation
3 are only runnable with HMI
firmware V11.xx.yy.
TopCon devices of the generation
4 T(TopCon Quadro) are only
runnable with HMI firmware
V4.xx.yy or V5.xx.yy.
Dont use devices of the generation 3 with devices
of the generation 4 in the same multi-unit system.
Only
HMI
CC
HMI/RCU did not
receive CFL
A HMI/RCU has not received a re-
quest to log on to the system.
Error resulting of a CAN bus error. Cf. 60) and 61)
Only
HMI
CD
HMI/RCU received
invalid CFL
Invalid login attempt
Subsequent error to CC)
Cf. CC)
Only
HMI
CD
HMI/RCU received
invalid CFL
Invalid login attempt
Communications error.
Cf. 60) and 61)
Only
HMI
CD
HMI/RCU received
invalid CFL
Invalid login attempt
Wrong CAN protocol.
Use only compatible HMI and controller board
software.
Only
HMI
CE
HMI/RCU did not
receive EOL
Invalid login attempt
See Error CD)