Error message
TopCon (Long)
Description
Possible Cause
Counteraction
14-12 DB
Number of multi-
load modules does
not correspond with
the given value
The total number of devices doesn’t
match the default.
Cf. D6) and D7).
Cf. D6) and D7).
14-13 DC
Slave ID or ad-
dress (RSC on) out
of range
The module ID or address (RSC on)
of a slave is out of the allowed
range.
Not more than 8 devices can be
connected in serial or parallel
connection.
reduce devices
14-14 DD
Invalid HMI/RCU ID
(out of range)
HMI ID is out of the allowed range.
HMI ID is out of the allowed range.
Configuration of ID to be corrected by using the
HMI.
14-15 DE
TC.LIN ID invalid
TC.LIN ID is outside of the allowed
range.
TC.LIN ID is outside of the al-
lowed range.
Use TopControl connected to TC.LIN device to set
TC.LIN ID to a value between 0 and 7 (including 0
and 7).
14-16 DF
TC.LIN ID not
unique
TC.LIN ID exists more than once.
TC.LIN ID exists more than once. Replace twice-assigned TC.LIN IDs.