9
Flash
Code
Error
Error message
TopCon (Long)
Description
Possible Cause
Counteraction
15-11 EA
TopCon 230VAC is
not supported on all
devices
The system is not configured as
230VAC system.
Master or Slave(s) in system are
not configured as 230VAC Top-
Con.
Check if all modules in system are 230VAC Top-
Con's.
Contact customer support
15-12 EB
Switchable Output
Capacitance is not
supported on all
devices
The Switchable Output Capacitance
option is enabled but is not support-
ed by all devices.
At least on one slave the Switcha-
ble Output Capacitance option is
not installed.
Using the system is possible with some dynamic
limitation
15-13 EC
TC.P.LIN is not
supported on all
devices
The system is not configured as
TC.P.LIN (TopCon and TC.LIN com-
binied in one device).
Master or Slave(s) in system are
not configured as TC.P.LIN (Top-
Con and TC.LIN combinied in one
device).
Check if all modules in system are TC.P.LIN
(TopCon and TC.LIN combinied in one device).
Contact customer support
15-14 ED
S3R-Mode is not
supported on all
devices
The system does not support the
S3R-Mode.
Master or Slave(s) in system are
not support the S3R-Mode.
Contact customer support
15-15 EE
Sub-Systems with
GSS in series con-
nection are not
supported
Sub-Systems with GSS in series
connection are not supported.
Sub-Systems with GSS are con-
nected in series.
Check if all Sub-Systems are connected in paral-
lel.
15-16 EF
Active rectifier is
not supported
The device is configured for active
rectifier mode but hardware and/or
IBC firmware do not support this
mode
Wrong setting or tried to run de-
vice with old hardware and/or old
IBC firmware
Contact customer support