Manual - TC.P Quadro
G) IBC System
2016-08-05
309/330
V04.52
9
9.1.17.
G) IBC System
Flash
Code
Error
Error message
TopCon (Long)
Description
Possible Cause
Counteraction
17-1
G0
Powerup from
watchdog reset
Internal Firmware Reset on IBC
board ocurred
Internal problem
Contact customer support if not because of a user
executed system reset
17-2
G1
Powerup from
software reset
Internal Firmware Reset on IBC
board ocurred
Internal problem
Contact customer support
17-3
G2
EEprom (queue
overflow or un-
known page)
Error on writing to IBC internal
EEprom
Internal timing problem or hard-
ware defect
Retry to store settings and restart device. If the
error keeps occuring contact customer support
17-4
G3
IBC heatsink tem-
perature sensor
unknown
Requested IBC heatsink temperature
sensor not supported
Wrong parameter or problem after
firmware downgrade because the
older firmware does not support
newer settings
Contact customer support
17-5
G4
Heatsink tempera-
ture too high
IBC heatsink temparature too high
Insufficient cooling, ambient tem-
perature too high
Lower ambient temperature or reduce the DC cur-
rent
17-6
G5
PCB temperature
too high
IBC electronic board temperature too
high
Insufficient cooling, ambient tem-
perature too high
Lower ambient temperature or reduce the DC cur-
rent
17-7
G6
IBC heatsink tem-
perature sensor
missing
IBC heatsink temperature sensor
missing
Cable break or sensor defect/not
connected on temperature meas-
urement
Contact customer support
17-8
G7
Inverter heatsink
temperature sensor
missing
Inverter heatsink temperature sensor
missing
Cable break or sensor defect/not
connected on temperature meas-
urement
Contact customer support