Manual - TC.P Quadro
U) Configuration 3
2016-08-05
323/330
V04.52
9
9.1.28.
U) Configuration 3
Flash
Code
Error
Error message
TopCon (Long)
Description
Possible Cause
Counteraction
29-1
U0
Sub-System ID or address (RSC on) in
TC.MAC system not unique
More than one Sub-
System in a total system
have the same Sub-
System ID or address
(RSC on)
All Sub-System ID's or addresses
(RSC on) within a TC.MAC system
must be unique
Check Sub-System ID's or addresses
(RSC on) by using TopControl PC
software
29-2
U1
More than one TC.MAC detected
More than one TC.MAC
in a total system detect-
ed
More than one TC.MAC in a TC.MAC
system
Make sure only one TC.MAC is con-
nected to a TC.MAC system
29-2
U1
More than one TC.MAC detected
More than one TC.MAC
in a total system detect-
ed
Configuration error within a Sub-
System
Contact customer support
29-3
U2
Nominal power of Sub-Systems not
consistent
Nominal voltage not
identical on all Sub-
Systems
Error while Subsystem login or config-
uration.
29-3
U2
Nominal power of Sub-Systems not
consistent
Nominal voltage not
identical on all Sub-
Systems
Different number of serial devices in a
Sub-System.
29-3
U2
Nominal power of Sub-Systems not
consistent
Nominal voltage not
identical on all Sub-
Systems
Different nominal voltage values in the
devices of the Sub-Systems.
29-4
U3
Nominal voltage of Sub-Systems not
consistent
Nominal power not iden-
tical on all Sub-Systems
Error while Subsystem login or config-
uration.
29-4
U3
Nominal voltage of Sub-Systems not
consistent
Nominal power not iden-
tical on all Sub-Systems
Different number of devices in a Sub-
System.
29-4
U3
Nominal voltage of Sub-Systems not
consistent
Nominal power not iden-
tical on all Sub-Systems
Different nominal power values in the
devices of the Sub-Systems.
29-5
U4
Nominal current of Sub-Systems not
consistent
Maximum current not
identical on all Sub-
Systems
Error while Subsystem login or config-
uration.