Manual - TC.P Quadro
W) Internal 2
2016-08-05
329/330
V04.52
9
9.1.30.
W) Internal 2
Flash
Code
Error
Error message
TopCon (Long)
Description
Possible Cause
Counteraction
31-1
W0
Powerup from
watchdog reset
The software executed an internal
reset due to an internal watchdog
timeout
Internal problems
Contact customer support
31-2
W1
TC.MAC sense
connector not at-
tached
TC.MAC sense cable not connected Wrong configuration
Deaktivate the TC.MAC sense input.
Contact customer support
31-2
W1
TC.MAC sense
connector not at-
tached
TC.MAC sense cable not connected
The TC.MAC interfaces X550.1,
X500.2, X500.3 or X500.4 are not
connected with a sense cable
Check if the sense connector is connected correct-
ly
31-3
W2
Invalid Bootloader
Version
Bootloader Version is invalid or too
old
Actual Firmware requires a higher
Bootloader version to operate
correctly
Contact customer support
31-4
W3
Update firmware
ignored (not load-
ed)
Update firmware is installed but was
not loaded. Factory default firmware
was loaded instead
Firmware check failed or firmware
ignored to prevent compatibility
issues
Contact customer support
31-16 WF
Unknown tripzone
err
The powerstage was switched off
automaticaly, but none of the known
errors are pending
Internal problem
Contact customer support