Manual - TC.P Quadro
Technical data
2016-08-05
36/330
V04.52
3
3.1.3.
Control
Remote programming
Analogue operation X105
Input impedance 20 k
Voltage set value
0
– 10 V
DC
for 0
– 100 % V
nom
Current set value
0
– 10 V
DC
for 0
– 100 % I
max
Power limit
10
– 0 V
DC
for 0
– 100 % P
nom
Internal resistance
simulation
3
0
– 10 V
DC
for 0
– R
max
Digital operation
(interfaces)
RS-232
1
; HMI
2
; TC.CANOpen
2
; TC.GPIB
2
;TC.USB
2
Isolation in relation to
mains voltage
2500 V
AC
Table 17
Analogue and digital operation.
1
Standard,
2
Option
3
Maximum resistance value as standard 1.2
or optional : 3.2
Accuracy
– measurement resolution
1
Analogue input and output
0.1 % at 10-bit resolution
Actual voltage
0.025 % at 12-bit resolution
Actual current
0.025 % at 12-bit resolution
Temperature measurement
0.2 °C
Table 18
Measuring accuracy of the TopCon power supply.
1
Absolute value or referred to nominal values.
Times
Starting time
Control electronics
1
5.0 s
Power section
2
0.1 s
Cycle times
Power section
25.0 µs
Voltage and
current controllers
50.0 µs
Power controller
50.0 µs
Protection
and monitoring
50.0 µs
State machine
1.0 ms
System communication
1.0 ms
Table 19
Starting and cycle times for a TopCon power supply.
1
After switching on the mains voltage.
2
After output voltage enable.