Manual - TC.P Quadro
Commissioning
2016-08-05
45/330
V04.52
3
3.2.
Commissioning
3.2.1.
General information
TopCon power supplies are built-in devices for a fixed connection to the
electrical supply system. They must be correctly mounted and installed
in compliance with the applicable regulations and standards.
In the countries of the European Union (EU), to place systems with in-
tegrated TopCon power supplies on the market the system or machine
must comply in particular with the following standards:
Low voltage directive
EN 50178
EC EMC directive
EN 61000-6-2
EN 61000-6-4
TopCon power supplies are prepared so that they can be installed,
wired and interference suppressed in accordance with the applicable
regulations with as little effort as possible. Nevertheless, the responsi-
bility for the compliance of systems and machines with built-in TopCon
power supplies remains with the manufacturer of the system or ma-
chine.
On the usage of the electrical power supply in certain application areas,
the related applicable standards and health and safety regulations are
to be followed.
3.2.2.
Safety information
Possible mortal danger due to electric shock!
Avoidance:
Never connect or disconnect electrical connections while they
are live.
Do not open the device if it is in operation, as it contains live
parts.
Lay cables carrying high currents using an adequate cable
cross-section.
Wait min. 5 minutes!
In the devices built-in there can be dangerous voltages after
switching off the mains voltage, as well as in case of
loads that store energy.
Only use the devices for the intended application and type of
load.
In particular, the mains voltage and load must match the in-
formation on the type plate, as well as the settings on the de-
vice.
Protection against touching the output current bars!
E.g. by fitting a suitable case.