Manual - TC.P Quadro
Commissioning
2016-08-05
53/330
V04.52
3
Control connections
The standard version can be switched on and off as well as remotely
programmed via digital and analogue inputs and outputs or directly via
the RS-232 interface.
The entire control and monitoring is undertaken by a powerful controller
(LP CTR) based on a DSP.
Further interaction options are provided via optional interfaces (e.g. RS-
422, GPIB (SCPI command set) or CAN/CANOpen®).
Isolation
All control interfaces are isolated in relation to the power line,
earth and output.
The analogue inputs and outputs are isolated in relation to the
power line, earth, output and digital interfaces.
The RS-232 interface is isolated in relation to the power line,
earth, output and controller.
The connections given above are described in more detail in this sec-
tion:
Name
Interface
Mains connection
3~ 400/480 VAC
Sense
X103 remote voltage sensor/
Correction of the voltage drop as measurement is
made directly at the load.
Output (voltage)
0
– U
NOM
Communication bus
X101/102, device communication (only TopCon and
dedicated peripheral devices, not a general interface)
Digital control I/O
X105
Analogue control
X105
Table 33
Overview of interfaces described in this section.