Manual - TC.P Quadro
HMI and RCU
2016-08-05
154/330
V04.52
6
Main screen
Status:
Ready
0.2 V
0 A
15.9 kW
0.2 V
2 A
15.9 kW
Status:
Ready
FGen [V]
FGen [A]
FGen [kW]
0.2 V
2 A
15.9 kW
1
2
5
4
3
1
2
3
Fig. 86
Main screen without (DISPLAY 1), left, and
with enabled and activated TFE option (DISPLAY 2), right
Main screen without/with enabled option TFE
– DISPLAY 1, 2
1
Status line
The system state is displayed:
Ready:
Device is ready for operation, the output is electrically isolat-
ed and the power semiconductor is inhibited.
Running:
Device is in operation, the output is providing power.
If a load is connected current flows.
Warning:
Device is still in operation, warning limit is exceeded, an
error may be approaching, e.g. over-temperature.
Indication: warning in the message bar
-2-.
Error:
Device is not ready for operation, the output is electrically
isolated and the power semiconductor is inhibited.
Indication: error in the message bar -2-
STOP:
Is generated by the TopControl application on an update to
the firmware for the TopCon power supply.
The control electronics are inhibited. The output is electrical-
ly isolated and the power semiconductor is inhibited.
After the update the device must be switched off briefly via
the circuit breaker and then switched back on again.
2
Message bar
Short description in case of error messages and warnings.
E.g. “Communication” message if the interlock connector is not fitted.
3
Actual values
Indication of the actual output values: voltage U, current I and power P.
4
Set values
Indication of the reference values: voltage U, current I and power P.
5
TFE display
If the function generator option is enabled and activated, set value
-4-
chang-
es to “FGen”. The change in the indication to “FGen” appears as per the func-
tion sequence set.
See DISPLAY 23, 31 function generator Fig. 93, page 161.
Table 80
Parameters on the main screen DISPLAY 1, 2