Manual - TC.P Quadro
TopControl application
2016-08-05
189/330
V04.52
6
6.4.7.3. Tab
– <FUNCGEN> (option)
Option name
TFEAAPControl (TopCon Function Generator Engine)
User level: from Standard User
If the TFEAAPControl option is not enabled, it can be operated in the
Demo mode
1
2
3
4
Fig. 110
Overview of the <FUNCGEN> tab.
The FUNCGEN tab can be divided into four groups to describe the indi-
vidual function units of the function generator.
Overview of the groups on the <FUNCGEN> tab
1
General setup,
see Table 110, page 190
Here the function generator can be switched on and off, reference values can
be searched for and functions loaded or saved.
2
Function Sequence,
see Table 112, page 194
Function definitions
-3-
made are combined into function sequences. It is pos-
sible to define a pause after a function sequence or which reference value is
to be present on the output after a function sequence.
3
Function Block,
Definition of the function parameters for the base functions that are used as
the basis for function blocks. For information on the creation of user-defined
and AAP curves see Table 115, page 199.
4
Function indication
Graphic of the functions sequences defined using
-3-
and
-2-
.
Table 109 Group overview on the <FUNCGEN> tab.