“Function Sequence” group on the <FUNCGEN> tab
1
3
2
4
Fig. 114
“Function Sequence” group.
<FUNCGEN> tab
– “Function Sequence” group
1
Repeat Function Block(s),
group
“continuously”,
option
Selected:
The function sequence is repeated continuously.
“times” text box is deactivated.
“times”
option and text box
Selected:
The function sequence is repeated the number of times
entered.
“continuously” option is cleared.
Value range:
1
– 276447231 (repetitions)
2
Delay between repeats,
text box
Pause between the repetitions of a function sequence.
Value range:
0 s
– 100000 s, step width: 0.0001 s; default: 0 s
3
“Trigger mode”,
list box
The event that triggers a function is defined.
“Voltage on”
Function sequence is triggered as soon as <VOLTAGE ON>
is clicked.
(See <CONTROL> tab, actuation of the <VOLTAGE ON>
button).
“Manual”
Manual triggering via the <Start> button in TopControl, see
Fig. 115, page 195 or via HMI/RCU see Table 88, page 164.
“High level on X105/19”
There is a high level on interface X105 on pin 19.
Condition:
Device status “VOLTAGE_ON”
(power at the device output).
4
After Function Sequence finished,
list box
State of the device output after the end of the function sequence.
“Voltage off”
No power at the output.
“Hold level”
The last value in the function sequence is present on the
output.
“Use level from std. input”
It is attempted to reach the reference value specified by the
active interface on the device output.
Table 112
Parameters in the “Function Sequence” group.