6
Creating user-defined functions
(“User defined Base Functions”)
“User-defined functions” are reference value functions in relation to the
time axis.
1
2
3
5
6
7
8
9
4
10
11
Fig. 118
Function generator - example of a user-defined function.
“Edit user defined Functions” window – parameters
1
time values,
list box
relative:
The time information for a point refers to the previous point.
absolute:
The time information for a point refers to the start of the
curve.
The selection has an effect on the position of points, see ,
-9-
2
select Function Block...,
list box
The list box contains the reference values that are selected in the “General
setup” group. See “Conditions for user-defined curves” Table 115, page 199.
3
edit Base Function,
list
If the times specified are changed via the Time prescaler
-8-
, the time infor-
mation is recalculated accordingly.
The amplitude of the reference value remains constant.
Edit points by double-clicking the line using the left mouse button.