Manual - TC.P Quadro
General information
2016-08-05
29/330
V04.52
2
2.2.5.
Parameterisation
– the process in principle
The basic principle of the control of the TopCon Quadro power supply is
based on the provision of parameters. After the necessary parameters
have been entered in the power supply, the power supply operates au-
tonomously.
Parameters
– definition
The term parameter covers the following data:
Limits, settings and specified values.
Control and program options for the power supply.
You will find further information on control variables and their uti-
lisation in the separate part of the manual and in special manu-
als. (See gridfile listing page 214).
Depending on the type of data, the data are saved differently internally
and processed internally by the power supply.
Peripherie
DSP
RAM
Main
DSP
RAM
Modulator
DSP
RAM
I/O
RS-232
Power
Amplifier
Flash
EEProm
PC
Software
TopControl
Gridfiles
Gridfiles
Gridfiles
TopCon Quadro
4
5
6
3
1
2
7
Fig. 7 Scheme: setting the parameters for the control of the TopCon Quadro.
Parameters that are cached in RAM are lost when the device is re-
started.
TopControl application
Parameters can be changed or transferred to the power supply using
the TopControl application (graphical user interface) (Peripheral DSP -
1-).
These parameters can be read into the software as gridfile parameter
sets
-2-
(for short: gridfile) and passed to the Peripheral DSP
or saved on the PC as a file.