Manual - TC.P Quadro
Commissioning
2016-08-05
62/330
V04.52
3
Assignment of interface and dummy plug
X102
CAN TERM
CTR 4
3
X105
Interlock CTR 4
1
X101
CAN TERM
Interlock CTR 4
2
Fig. 27
Schematic illustration of the D-Sub dummy plugs used with their
labelling.
Dummy plug
1
Interlock connector, D-Sub, 25-pin (dummy plug)
Label: “
X105; Interlock CTR 4”
Is connected on the rear side of all devices to interface X105.
2
Interlock or CAN-Term, D-Sub, 9-pin (dummy plug)
Label: “
X101; CAN TERM; Interlock CTR 4
“
Is connected to interface X101 on the rear side of the device at the start of the
CAN multi-unit system.
3
CAN-Term, D-Sub, 9-pin (dummy plug)
Label: “
X102; CAN TERM;”
Is connected to interface X102 on the rear side of the device at the end of the
CAN multi-unit system.
Table 38
Dummy plugs and their labelling.
Only one CAN-Term is allowed to be connected to a single device.
Independent of whether X101 or X102 is used.
Establishment of communication connection
TopCon with/without HMI and RCU
In the following the configuration of a TopCon power supply and its pe-
ripheral devices is considered.
With the possible combinations of HMI and RCU, there are 4 standard
configurations for a TopCon power supply.
For further information on multi-unit systems with at least 2 or more
TopCon power supplies, see chapter 5, from page 131 .