If the voltage of the TopCon device is not stable the device will try again
and issue a warning after 10 retries: “RPP-Voltage unstable”.
Regardless of this warning the device will continue with retries.
In case of reverse polarity:
If negative voltage is measured with the sense, an error message
appears: “Sense polarity”.
The device goes into error state. To get access to the device again, you
have to change the polarity of the battery and confirm the error
message.
In case of the DC relay (switch, which is built in additionally) will not be
activated (not closed). The voltage U
Rail =
U
Batt
applies at the rail lines.
No current will flow into or from the battery.
Power off
At power off the DC relay needs a short time
-8-
to open the
connection, because of its mechanical inertia. Meanwhile the TopCon
decreases its output voltage.
The voltage at the rail lines U
Rail
equates to the voltage U
Batt
-10-
.
When the DC swich opens, the battery will be disconnected from the
device and its internal base load resistance. The battery will not further
discharged by the internal resistance.
For further Information and the RPP configuration,
refer to appendix in chapter 9.2, page
Fehler! Textmarke nicht
definiert.
.
1.2.3.
General view
For further information refer to the TopCon TC.GSS manual.