5. Installation and commissioning
5.1. Safety information
Possible mortal danger due to electric shock!
•
Due to tampering with electrical components.
•
Connecting the supply and DC cables.
Avoidance:
⇒
The electrical installation is to be undertaken by personnel
with electrical training.
⇒
Never connect or disconnect electrical connections while they
are live.
⇒
Lay cables carrying high currents using an adequate cable
cross-section.
⇒
Pay attention to the information at the position of the hazard.
⇒
Wait up to 15 minutes! In the devices built-in there can be
dangerous voltages after switching off the mains voltage, as
well as in case of loads that store energy.
⇒
Only use the devices for the intended application and type of
load. In particular, the mains voltage must match the
information on the type plate, as well as the settings on the
device.
⇒
Protection against touching the output bus bars! E.g. by fitting
a suitable housing.
For further information on the general safety instructions,
DANGER