6)  Start and Stop for Heating 

 

Heating  Start

:  Heating  is  started  based  on  the  selected  program. 

From  the  current  temperature  to  the  set  temperature  of  STEP1, 
temperature  is  increased  at  3  degree  per  second.  When  set 
temperature is reached, the temperature is maintained for a period 
of time of setting values. After that, heating is carried out according 
to the set values of STEP2 and STEP3. 

 

Extension  time

:  Each  time  the  "UP"  button  is  pressed  once  in 

STEP3,  the  heating  holding  time  can  be  further  extended  by  30 
seconds. 

       

 

Stop

:  When  you  press  the  Stop  button  to  terminate  the  heating 

operation, upper and lower heater will cool down to 40 degree. After 
that, cooling function will stop and the system will switch to standby 
mode. 

 

Restart

:  When  you  resume  the  heating  operation  after  pressing 

program stop button, the heating  does not proceed  at temperature 
higher  than  80  degree  even  if  start  button  is  pressed.  As  the 
temperature drops to 80 degrees or less, the heating operation can 
proceed.   

 

Heating Pause of Upper heater:

 In order to stop the heating of the 

upper  heater  during  operation,  if  the  upper  heater  is  pushed  back 
about 4 cm, a physical  weak jam is confirmed and its power is cut 
off. 

The  fans  will  continue  to  operate  and  "UP"  and  "OFF"  will 

illuminate  on  the  temperature  display.  At  this  time,  the  program  in 
progress is continued, and when the upper heater is pulled forward 
again, the pause function is canceled and the Upper heater begins 
to rise to the temperature of the current ongoing stage.

 

 
 

 
 

5. Maintenance of the products

 

1)  Unplug the power cable when the product is cleaned.   
2)  Use dry cloths when the product is cleaned. 
3)  Do not store flammable materials near equipment as this is a heating 

device. 

4)  Tearing  down  of  the  products  is  strictly  prohibited.  We  will  not  be 

held responsible for malfunctions caused by disassembly. 

5)  When the product is not in use for prolonged period of time, remove 

the power plug from electrical outlet and store in a dry place. 

 

6. Troubleshooting 

 

1) When the product does not turn on 

  When smoke is emitted from the upper heater or the lower heater 

during  operation.  Power  off  immediately  and  ask  for  A/S 
consultation. 

  Check the power supply. 

  Make sure if the upper heater is pushed backward. 

(At  the  start  of  heating,  the  upper  heater  must  be  fully  pulled  to 
the front.) 

  Check if it is not a power failure. 

 

  2) When temperature does not rise. 

  Check if the temperature rises during heating.   

  Make sure if the upper heater is pushed backward. 

(At  the  start  of  heating,  the  upper  heater  must  be  fully  pulled  to 
the front.) 

  Check the operation statues of heater. 

 

  3) Error message 

During malfunction, t

hree times of buzzer sound, “beep” and error   

message will be displayed as below. 

 

"UP" "th": Defective thermal sensor of Upper heater 

 

"LO" "th": Defective thermal sensor of Lower heater 

 

"U-H" "OFF": Improper temperature rise of Upper heater   

 

"L-H" "OFF": Improper temperature rise of Lower heater 

 

www.regeni.com                                    -8- 

www.regeni.com                                  -9- 

Summary of Contents for BK-200S

Page 1: ...page Thank you so much for purchasing the product of Regen i Our company has always been dedicated to customer satisfaction This user instruction and manual describes the functions of your purchased product and instructions and precautions for handling and using the product All users of this product must read and understand the contents of this user instruction and manual before using and or handl...

Page 2: ... are clearances of at least 10 cm between all sides of the products and the environment 4 Avoid heat sources or direct sunlight 3 Handling the products 1 Do not touch the power cord and other electrical components with wet hands 2 Be sure to wear heat resistant gloves for operation because it is a heating device 3 When the nozzle is replaced please make sure to wear heat resistant gloves requisite...

Page 3: ...perature time and airflow settings of user s set up only for program number 6 9 Button to increase numerical value When heating in the third step remaining time can be extended by 30 second per one pressing Button to decrease numerical value Start and Stop for operation 4 Initial Setting Program Graph Default value Factory setting Prog Sort Step1 Step2 Step3 Applied parts 1 Temperature 100 180 230...

Page 4: ... can be maximum 120 seconds UPPER and S1 lamp are turned on and Temp Screen Blinks Set temperature of STEP1 by UP DOWN button and press SET button Then TIME on display is blinking and change time of STEP1 in same way Change temperature and time of STEP2 and STEP3 of the upper heater sequentially Upper air volume can be adjusted by 1 3 steps Change the lower heater setting in the same way as the up...

Page 5: ...ulled forward again the pause function is canceled and the Upper heater begins to rise to the temperature of the current ongoing stage 5 Maintenance of the products 1 Unplug the power cable when the product is cleaned 2 Use dry cloths when the product is cleaned 3 Do not store flammable materials near equipment as this is a heating device 4 Tearing down of the products is strictly prohibited We wi...

Page 6: ... and custom shall be borne by you 3 Warranty Exception In the following cases it will be subject to No Free Repair within the warranty period 8 PRODUCT SPECIFICATIONS Product Name Smartphone Rework System Model BK 200S Power AC 200 240V 50 60Hz Max Watts 1600 W Max Current 7 A Size L 380mm x W 230mm x H 260mm Weight 7kg Country of Origin MADE IN KOREA Manufacturer REGEN I INC Address 1109 Daeryung...

Reviews:

Related manuals for BK-200S