background image

Oil-lubricated Compressors 

Ölgeschmierte Kompressoren

 

 
 

 

OPERATING INSTRUCTIONS 

 

 

BEDIENUNGSANLEITUNG 

 

 

 

Profi-AirTec 128-8-1.1 

Profi-AirTec 210-8-1.8 

 

 

 

(P-AT128-8-1.1) 

(P-AT210-8-1.8) 

 

 

 

 

 
 

Profi-AirTec 380-8-2.5

 

Profi-AirTec 670-8-5.3

 

 

 

(P-AT380-8-2.5)

 

(P-AT670-8-5.3)

 

 

 

 

 

 

 

Profi-AirTec 1050-12-7.0 

 

 

  (P-AT1050-12-7.0)

 

 

 

 

 

 
 
 
 
 

 
 
 
 
 

 
 

 

Contents 

 
 

English 

1-6 

 

Deutsch 

7-11 

 

1.  Introduction 

2.  In general 

3.  Ranges of application 

4.  Preparation and statring 

5.  Operation 

2-3 

6.  Security tips 

7.  Cautions 

8.  Maintance 

9.  Electric principle & wiring diagram 

10.  Guarantee

 

regulations 

11.  Troubleshooting 

12.  Technical Data 

 
 
 
 
  
 
 
 
 
 
 
 

 

 
 

 

 

 
 
 
 
 
 
 

 
 

 

 

ENGLISH 

Summary of Contents for Profi-AirTec 128-8-1.1

Page 1: ... 5 Profi AirTec 670 8 5 3 P AT380 8 2 5 P AT670 8 5 3 Profi AirTec 1050 12 7 0 P AT1050 12 7 0 Contents English 1 6 Deutsch 7 11 1 Introduction 2 2 In general 2 3 Ranges of application 2 4 Preparation and statring 2 5 Operation 2 3 6 Security tips 3 7 Cautions 3 8 Maintance 4 9 Electric principle wiring diagram 4 10 Guarantee regulations 5 11 Troubleshooting 5 12 Technical Data 6 ENGLISH 1 ...

Page 2: ...ggle on 0 1 The compressor is controlled by pressure switch when normal working It can be stopped automatically as pressure increasing to the maximum and restart as pressure decreasing to the mnimum The rated pressure has been adjusted when produced Don t change it carelessly As soon as motor switched off the compressed air in the dicharge pipe should be released through the release valve under th...

Page 3: ...ly informed service staff By use of not original spare parts The operator has to provide on his own responsibility for The security regulations are kept A not designated use as well as a faulty installation or inadmissible usage are excluded and that a designated use is guaranteed when the compressor is used according to the by contract agreed application terms Moreover we perform no compensation ...

Page 4: ...stung Anzahl Zylinder Motordrehzahl Spannung Stromstärke Schutzart Isolationsklasse Schallleistungspegel Kabellänge English Engine power Tank size Max pressure Max air pressure output Number of cylinders Engine speed rpm Tension Amperage Protective class Isolation class Noise level Cable length Engine power Tank size Max pressure Max air pressure output Number of cylinders Engine speed Tension Amp...

Page 5: ...chalter schaltet den Motor automatisch aus wenn der maximaler Druck erreicht wird und startet den Motor neu wenn der minimaler Druck erreicht wird Der Nenndruck wurde in Produktionsprozess angepasst Verändern Sie die Einstellung nicht nachlässig Sobald der Motor abgeschaltet wird sollte die Druckluft in die Druckleitung durch das Ventil freigegeben werden Dies ist die notwendige Voraussetzung für ...

Page 6: ...satzteilen Der Betreiber hat in eigener Verantwortung dafür zu sorgen dass die entsprechenden Sicherheitsbestimmungen eingehalten werden dass eine nicht bestimmungsgemäße Verwendung sowie eine fehlerhafte Aufstellung oder Inbetriebnahme und ein unzulässiger Betrieb ausgeschlossen sind und dass darüber hinaus eine bestimmungsgemäße Verwendung gewährleistet und der Kompressor entsprechend den vertra...

Reviews: