City Series CV72EPV
|
105
maintenance
End of Line Power Vent Maintenance
Internal Power Vent Access
Note: May only be accessed if an access panel was installed for servicing
from inside.
1. Turn off the power.
2. Remove 8 Phillips head screws from the rear of the power vent (see Diagram 1).
3. Slide the power vent housing out through the back as shown in Diagram 2.
4. Turn the power vent over to the front side (Diagram 3).
5. Follow Steps 1-9 on previous page.
Front of power vent
Diagram 1
Diagram 2
Diagram 3