16
|
City Series CV72EPV
owner's information
Proflame II Remote Control Operating Instructions
Figure 2: Transmitter LCD Display
OPERATING PROCEDURE
Pairing the remote control to remote receiver/battery
holder (if required)
Power the receiver. Press the PRG button located on the top right hand
corner of receiver. The receiver will beep three times to indicate that it is
ready to synchronize with a transmitter. Install the 3 AAA type batteries
in the transmitter battery bay, located on the base of the transmitter (fig.
3). With the batteries already installed in the transmitter, opush the ON
button. The receiver's command is accepted and sets to the particular
code of that transmitter. The system is now initialized.
(*) The receiver may be independent or integral jto the IFC hearth appliance
control module. The receiver instruction may not be independent when
part of the IFC.
Figure 3: Battery Compartment
WARNING: THE TRANSMITTER AND IFC ARE RADIO FRE-
QUENCY DEVICES.
The Proflame 2 Transmitter provides for controlling the following hearth
appliance functions:
1. Main Burner On/Off
2. Main Burner flame modulation (6 levels)
3. Choice of standing or intermittent pilot (CPI/IPI)
4. Thermostat and Smart thermostat functions
5. Accent light modulation (6 levels)**
6. Split flow valve**
7. Comfort Fan speed modulation (6 levels)**
** This feature is not available on any Hampton models.
IMPORTANT:
The Proflame Transmitter 2 is an integrated part of the
Proflame 2 System, which consists of these elements:
• Proflame 2 Transmitter, to be used in conjunction with:
• Integrated Fireplaces Control (Proflame 2 IFC)
The Proflame Transmitter uses a streamline design with a simple button
layout and informative LCD display (Fig. 1). A Mode Key is provided to
index between the features and a Thermostat Key is used to turn on/off
or index through Thermostat functions (Fig. 1 & 2). Additionally, a Key
Lock feature is provided (Fig. 22).
TECHNICAL DATA
REMOTE CONTROL
Supply Voltage
4.5V (three 1.5V AAA batteries)
Ambient temperature
ratings
0 - 50
o
C (32 - 122
o
F)
Radio Frequency
315 MHZ
ATTENTION!
- Turn “OFF” the main gas supply of the appliance during installation or
maintenance of the IFC.
- Turn “OFF” main gas supply to the appliance prior to removing or
reinserting the batteries.
- In case of remote control malfunction, turn off the IFC device using
the "ON/OFF" main switch.
- For installation / maintenance, switch off the IFC device removing
main power supply plug.