City Series CV72EPV
|
79
installation
LP Conversion Instructions
919-821
08.16.18
1
CITY SERIES
CONVERSION FROM NG TO LP
CV72E using SIT 885 NOVA Gas Valve
Caution: The gas supply shall be shut off prior to disconnecting the
electrical power, before proceeding with the conversion.
Always let the appliance cool to room temperature before servicing.
1 Remove the outer panels and safety glass — see manual.
2. Remove inner fi rebox glass — see manual.
3. Remove inner panels — see manual.
4. Remove all media installed on burner (glass, logs or stones, etc).
5. Lift off the far right base panel and loosen 2 screws on IFC cover--re-
moved cover to access IFC.
6. Disconnect the Cable coming from the Pressure Regulator Motor.
WARNING
This conversion kit shall be installed by a qualifi ed ser-
vice agency in accordance with the manufacturer’s in-
structions and all applicable codes and requirements
of the authority having jurisdiction. If these instructions
is not followed exactly, a fi re, explosion or production
of carbon monoxide may result causing property dam-
age, personal injury or loss of life. The qualifi ed service
agency is responsible for the proper installation of this
kit. The installation is not proper and complete until
the operation of the converted appliance is checked as
specifi ed in the manufacturer’s instructions supplied
with the kit.
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION!
Cable from motor
Conversion Kit 666-969 includes:
1
911-011
Stepper Motor LP for 885 SIT
1
905-014
Orifi ce #47
1
910-101
Pilot Orifi ce #35
1
918-590
Decal - Conversion to LP
1
908-528
Label Propane
1
904-529
5/32" long Allen Key
7. Remove and discard 2 Pressure regulator screws (A)using a (T20 or slot
screwdriver,) Pressure Regulator (B) and Spring and Diaphragm (C)
(see below).
8. Ensure the rubber gasket, which is prefi tted as part of the Assembly,
is properly positioned. Install the new Pressure Regulator using the 2x
M4 x .7 screws supplied. Tighten the screws to 25lb-in. In the event that
the screw threads are cross threaded or stripped, replace the valve as-
sembly.
Install the enclosed propane identifi cation label to the valve body where it
can be easily seen.
Pressure
regulator
screws
9. Re-attach the Pressure Regulator wire (disconnected in Step 6), and re-
situate the IFC, secure the screws that fasten the IFC Mounting Brackets.
10. Remove pilot hood by lifting up and off.
11. Remove the trim cover on right side of burner by lifting off. Also remove
the burner surround by sliding to the left and lifting off.
Trim cover
Burner Surround
Pilot hood
Base Panel
IFC cover
CB72E shown