F2450M Regency Freestanding Woodstove
|
9
installation
Room Air - Important
For installation using room air for combustion,
remove knockout from the pedestal, and/or from
the bottom if using a heat shield.
Mobile home installations require the use of
outside air.
Minimum Clearance To
Combustible Materials
Please read the section below carefully as clearances depend on whether the airmate or the rear
heat deflector is installed on the stove.
Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner, and from
the rear heat shield to a back wall.
Clearances may only be reduced by means approved by the regulatory authority.
Minimum ceiling height - 83" (2108mm)
On pedestal units there are two locations where
outside air may be adapted to the unit. If using
the bottom of the pedestal, do not remove knock-
out from the rear of the pedestal. Only remove
rear knockout if outside air will be brought in
from the rear.
On leg units outside air can only be brought in
from the bottom of the heat shield.
Note: Once the knockout is removed
there are two tabs remaining.
Bend both tabs out for ease of
installation when attaching out-
side air.
A
F
F
C
C
B
E
D
NOTE:
Be aware that local Codes and Regulations may override some clearances listed in this manual.
Check with your local inspector.
NOTE:
This clearance is also required for air space between the appliance and wall/ceiling.
Residential Installation “C” Vent (Single Wall)
Unit
From Unit
From Corner
From Flue Center-Line
A
B
C
D
E
F
Medium F2450M with Airmate
16" (406mm)
9.5" (241mm)
8" (203mm)
28" (711mm)
16" (406mm)
20" (508mm)
with Rear Deflector
16" (406mm)
11.5" (292mm) 8" (203mm)
28" (711mm)
18" (457mm)
20" (508mm)
Residential Close Clearance (To be installed with required pipe components)
When the stove is installed as a close clearance residential unit, a listed double wall connector is required from the stove collar to the ceiling level.
Unit
From Unit
From Corner
From Flue Center-Line
A
B
C
D
E
F
Medium F2450M with Airmate
15" (381mm)
8" (203mm)
6" (152mm)
27" (686mm)
14.5" (368mm)
18" (457mm)
with Rear Deflector
15" (381mm)
10" (254mm)
6" (152mm)
27" (686mm)
16.5" (419mm)
18" (457mm)
Mobile Home Close Clearance (To be installed with required pipe components)
"C" Vent single wall pipe is not approved for Mobile Home installations. (Refer to Mobile Home Instructions.)
Unit
From Unit
From Corner
From Flue Center-Line
A
B
C
D
E
F
Medium F2450M with Airmate
15" (381mm)
8" (203mm)
6" (152mm)
27" (686mm)
14.5" (368mm)
18" (457mm)
with Rear Deflector
15" (381mm)
10" (254mm)
6" (152mm)
27" (686mm)
16.5" (419mm)
18" (457mm)