U31-10 Gas Insert  |    1

U31 Gas Insert

Model

U31-NG10

U31-LP10

Fuel Type

Natural Gas

Propane

Minimum Supply Pressure

5” W.C. (1.25 kPa)

12” W.C. (2.99 kPa)

Manifold Pressure - High

3.5” W.C. (0.87 kPa)

10” W.C. (2.49 kPa)

Manifold Pressure - Low

1.6” W.C. (0.40 kPa)

6.4” W.C. (1.59 kPa)

Orifice Size -

Altitude 0-2000 ft.

#37 DMS

#52 DMS

Orifice Size - 

Altitude 2000-4500 ft.

#40 DMS

#53 DMS

Minimum Input  
Altitude 0-2000 ft. (0-610m)

20,600 BTU/h   

(6.04kW)

22,000 BTU/h 

(6.45 kW)

Minimum Input  
Altitude 2000-4500 ft. (610-1372m)

19,200 BTU/h   

(5.62 kW)

20,000 BTU/h 

(5.86 kW)

Maximum Input 
Altitude 0-2000 ft. (0-610m)

30,000 BTU/h 

(8.79 kW)

28,000 BTU/h 

(8.21 kW)

Maximum Input 
Altitude 2000-4500 ft. (610-1372m)

27,200 BTU/h 

(7.97 kW)

25,000 BTU/h 

(7.33 kW)

Vent Sizing

4” B-Vent

4” B-Vent

Approved Venting Systems

Flex Vent Systems:

FPI AstroCap™ Flex Vent

UNIT DIMENSIONS WITH STANDARD FACEPLATE

UNIT DIMENSIONS WITH LOW PROFILE FACEPLATE

8-1/8

” 

Low profile

Standard

Faceplate

8-1/8

” 

Low profile

Standard

Faceplate

MINIMUM FIREPLACE DIMENSIONS

The minimum fireplace dimensions for the FPI gas fireplace insert are shown in the following diagrams: