14
|
LRI3E-1 / HRI3E-1 Direct Vent Gas Insert
|
14
installation
Remove connector plate guide
Vent restrictor install
The LRI3E / HRI3E use a heat exchanger and efficient combustion technol-
ogy to provide extreme heating efficiencies. The more efficient an appliance
becomes, the lower the flue gas temperatures becomes.
On start-up, flue temperatures are required to initiate venting action.
Here are some considerations when setting up the LRI3E / HRI3E:
When operating the unit in temperatures below 50° F, run the pilot in "Standing
Pilot" mode, 1. Press and hold the small flame icon on the hand held remote
control to set the appliance at continuous pilot.
Note: If after 5 days the appliance has not had a call for heat, the pilot will
extinguish and will not be present. To enable pilot operation you will need to
repeat steps for continuous pilot operation.
STANDING PILOT
ALTERNATE APPROVED CAPS/ADAPTOR
tooltip
Flue connector
plate guide
tooltip
Restrictor
plate
Note: only installed on runs at the minimum 8 feet vent height from above unit.
If longer than 8 feet the restrictor is not required.
1. Remove flue connecter plate by sliding out toward the back of the unit - see
next page.
VENT RESTRICTOR PLATE INSTALLATION
46DVA-GK 3" Co-linear Adaptor with flashing
46DVA-VC Vertical Termination Cap
or
46DVA-VCH High Wind Cap
* 948-417/P 2” to 3” Increaser (Air inlet)
*Note : The 46DVA-GK Co-linear Adaptor with flashing comes with 2 - 3”
collars. The increaser is required to adapt the flex (air inlet side) which is 2
inch to the 46DVA-GK Co-linear Adaptor with flashing.
In areas of consistently high winds, we recommend using the Simpson
Dura-Vent System (46DVA-GK adapter and 46DVA-VCH high-wind cap). The
Air Intake pipe must be attached to the inlet air collar of the termination cap.
This chimney system is also ideal when the chimney termination is round in
applications where this appliance is being installed into a factory built fireplace.
2. Remove left flue connector plate guide by removing 2 screws as shown below.
3. Flip the flue connector plate gasket to the right (out of the way) to allow ease
of installation of the vent restrictor.
4. Install vent restrictor with 2 screws in location shown above.