LRI3E-1 / HRI3E-1 Direct Vent Gas Insert
|
27
|
27
installation
PAINTED BLACK AND ENAMEL PANEL INSTALLATION
Important: This appliance cannot be operated without brick (LRI3E), enamel panels (HRI3E/LRI3E) installed or painted
panels (HRI3E only) installed.
919-707
08.31.16
1
HRI3E
BLACK PAINTED OR ENAMEL PANEL INSTALLATION
Left Panel
Right Panel
Completed Install
Back Panel
Before you Start:
Black Enamel Panels Only
• Black Enamel panels must be inspected for scratches and dimples prior
to installation. All claims to be recorded at this time.
Claims for damage after installation will not receive consideration.
• Black Enamel panels will discolor a little during normal operation. This is
normal and should not be considered a defect.
*
All hand and finger marks
MUST
be cleaned off with a soft cloth. Use
an ammonia based cleaner (ie. glass cleaner) to remove any fingerprints
before applying heat to the unit.
Failure to do this will result in burn stains on panels which you will
be unable to remove.
Not protected by product warranty.
1. Carefully unpack painted black or enamel panels.
2. Install back painted/enamel panel - place against back wall of firebox, the
side panels (once installed) will secure the back panel in position.
3. Loosen bracket screw in firebox in location shown below, slide left panel
into position until it contacts the back panel. Slide the panel bracket on from
the front of the unit and tighten the bracket screw.
4. Loosen bracket screw in firebox in location shown below, slide right panel
into position until it contacts the back panel. Slide the panel bracket on from
the back of the unit and tighten the bracket screw.