LRI3E-1 / HRI3E-1 Direct Vent Gas Insert
|
44
maintenance
FAN REPLACEMENT - WITH REMOTE CONTROL
3.
Remove fan from unit by lifting up off pins.
4.
To reinstall - reverse steps.
2. Disconnect the fan wire harness through the rear panel. Disconnect 2 x
1/4" spade connectors to the fan terminals. Disconnect the ground lug to
the fan using the screw provided.
WARNING
Electrical Grounding Instructions
This appliance is equipped with a three-prong
(grounding) plug for your protection against shock
hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove the
grounding prong from this plug.
Diagram 3
Diagram 2
tooltip
Before you begin:
Shut off the gas supply to the unit.
Disconnect all electrical supply to the unit.
Always let the appliance cool to room temperature before servicing.
Note:
To access the rear access panel both the gas and venting will need
to be disconnected (see vent/flue installation in this manual) for
proper removal.
There is no access to the blower from the front of this appliance.
1. Remove 5 screws and loosen 2 screws along the bottom to remove fan
access panel -see Diagram 1.
Diagram 1
Ground
Spade connectors
= Remove
= Loosen